Overview

It is possible to control and schedule the screens in your digital signage network. The requirement for this to work is that

  • The player has a cable contact with the screen of a supported type, generally RS-232 or Ethernet, as well as working drivers for the port.
  • The screen communication protocol is known and implemented by DISE.
  • Currently, only Windows players have the ability to control screens.

Depending on the abilities of the screen protocol, using screen control you are able to:

  • Checking if a screen is on or off.
  • Turning a screen on or off
  • Getting screen temperature.
  • Getting specified screen parameters.

Currently supported screens

Model Select ID Control Power Control Input Read Status (Power) Read Input Read Signal Supplied Read FW Version Read Temperature Additional
Hantarex Yes Yes No Yes Yes Yes Yes No Read Model
JVC No Yes No Yes Yes No No No
KiSmart Yes Yes No Yes Yes No No Yes
LG Yes Yes No Yes Yes No No No
Mitsubishi No Yes No Yes Yes No No Yes
Mitsubishi Cube No Yes No Yes Yes Yes Yes Yes TCP Support
Mitsubishi Projectors No Yes No Yes Yes Yes Yes No
NEC Yes Yes No Yes No Yes No Yes
NEC (API) No Yes No Yes Yes Yes No Yes TCP Support
Panasonic No Yes Yes Yes Yes No No Yes
Pioneer Yes Yes No Yes Yes No No Yes
Projectiondesign No Yes No Yes Yes Yes Yes Yes Read Scaling, Read Lamp 1/2 Status, Read Lamp 1/2 Estimated Remaining Time, Read Fan Speed, Read Serial Number
Samsung Yes Yes No Yes Yes No No Yes Read Sensor States, Read Aspect, Read Brightness, Read Contrast, Read Color, Read Serial Number, Read Volume, Read Sound Mute, Read Sharpness, Control Volume
Sanyo No Yes No No No No No No
Sharp No Yes No Yes No No No Yes
Sony No Yes No Yes Yes Yes No No TCP Support
ViewPia Yes Yes No Yes Yes No No No Read Aspect

Screens that communicate using the same protocols as the ones above are of course supported.

Lightbulb.png Note: If you want to use an as-yet unsupported screen, please send us the RS232 or network communication spec for the screen/projector/LED and we can look at adding support for it.

DISE Cloud

Screen control requires that the monitoring add-on is licensed on the network. On the player, the screen control will be done by a screen communication service which is itself managed by DISE Control Center.

Setting up screen control

To set a player up with screen control,

  • Go into the player details.
  • Click Options > Control.

PlayerControl.png

  • Click the screen and click Edit.
  • Select the screen brand and model from the dropdowns.

ScreenManufacturer.png

  • Select the input method by which to communicate with the screen.
If the player has a COM port, it will have reported it while registering into DISE Server. If you have just recently installed drivers for a new COM port, please restart the player for it to register the new hardware into Server.

Schedule screen power

DISE Professional

Info.png Main article: DISE Screen Control